When you are installing a kitchen sink drain pipe along with the drain attachment on the floor you will need to be able to fit the drain and the parts together.
Kitchen sink plumbing through floor.
You can have this supply line come through the back wall or out of the floor depending on what is convenient.
I just found it and registered.
Cut a smaller opening in the ceiling for the vent pipe.
Tie the sink vent to the main vent stack by cutting into the main stack at a point above the highest plumbing fixture in the house with a hacksaw and installing a vent tee.
Adding another bathroom or relocating plumbing fixtures during a remodel requires running new drainpipes.
Anchor the drainpipe with straps.
Glue the vent pipe to it.
When it comes time to renovate the old kitchen and rip out the basin in the corner and install a new upgraded two basin sink a few feet from the wall or an island sink in the middle of the room the plumbing is most likely moored in a concrete slab in the flooring that must be taken out before the new pipes are installed and finishing work gets underway.
The only difficulty is that the existing drain goes through the concrete floor rather than curving into the wall.
In order to do this you will have to attach the drain to the s trap below your sink where it falls into the floor including applying putty and putting drains into the base of the sink adding the tailpiece and then fitting the t.
Bathroom sink drains through floor not wall 9 answers hello first let me say this a great forum.
Guide the vent pipe up through the hole and into the attic or room above and slip its lower end into the fitting at the floor.
Remove the nut from the end of the pipe that connects this sink drain with the one that has the p trap.
In most communities a permit from the local.
As far as the kitchen sink goes most of the code issues of concern to homeowners involve the drain and waste system.
Next remove the nut directly under the sink hole and pull down on the pipes.
I want to put in a kohler cimmaron pedestal sink in my bathroom.
Improperly installed drain and vent components can cause blockages water contamination and the release of dangerous sewer gases into the home and they can affect the plumbing in other parts of the house.
For a 1 1 2 inch vent pipe a 2 1 2 inch hole is sufficient.
How to install drain lines through the floor.
If there s a little water in the pipe clean it up immediately to prevent damage to the cabinet floor.
And it is about three inches off.
Having the water supply line come out of the back wall is the most common solution.